Note: This thermal material is not
electrically conductive but contains no substrate to prevent metal
to metal contact between component and heat sink.
Description: Thermaphase "Thermaps"
are solid rods of thixotropic (FSF-98) material which can be
used for manual or automatic attachment of components to heat sinks
(or PC boards).
When
the rod material is touched briefly to a heated surface, this
thermal interface material becomes a soft thixotropic substance
(much like thick shaving cream). The molten thermal materials
adheres to the heated surface when the Thermap is
removed. When a component is pressed down into the
molten material, it flows into the micropores of component and
heat sink, expulsing air from the pores. The distance between
component and heat sink decreases as the thermal compound flows into
the pores and surface irregularities. Excess FSF material is
extruded from under the component and forms a "bead" of material
around the perimeter of the component. The thinnest possible
interface is created. The excess material at the component
perimeter forms a seal around the component. Thermaphase FSF
material is not electrically conductive, but has no barrier in it to
prevent metal to metal contact between component and heat
sink.
This
material is Thermoplastic and exhibits RAB (Reversible Adhesive
Bonding). When the material has reflowed under heat and
pressure and then recools below the phase change temperature, it
bonds the component to the heat sink. The component can be
removed at any time by reheating. This can be done in
unlimited number of times. This product feature can be used to
adhere components to heat sinks replacing mechanical
fasteners.
You
can use these "Thermaps" for prototype work by simply "painting"
pads onto heat sinks or other flat surfaces. For production
work, the "Thermap" is brought down vertically each time and prints
the heat sink with a thermal pad similar to the rod cross sectional
shape. The tip of the rod retains its cross sectional shape
because the thermal material is thixotropic, non-flowing. When
the component is pressed onto the heat sink and the thermal
interface material allowed to change again to the solid state, the
component is firmly adhered to the heat sink (tensile strength
>25psi). |