Contact ETL
How to find us

Catalogues

 

PTC Heater Range

PTC - Self Regulating Heaters  

 

 

 

 
Dimensions
Design Notes
Power = KxAxT
K: Heat transmission factor, sheet steel 5.5W/m2 Kelvin
A: Complete surface area of heat losing enclosure (m2)
T Temprature difference between the ambient air temprature and the specified air temprature of the enclosure.
When considering cabinet heating, place the elements within the lowest part of the enclosure to aid natural convection of the thermal energy.
Assisted forced air convection enhances the power output, thus decreasing the temprature of the element.
       
Applications
      Electrical switch gear cabinets
      CCTV camera housing
      Telecommunication cabins
      Refrigeration drip tray heating
      Street Cabinets
      Laboratory Equipment
 
Specification
      UL, CSA, VDE
      0.5mm2 black silicon VDE approved wire
      100-240vac/dc, 10-30vac/dc
      IP54 on request
      Protection class II
      Custom models considered
 
Models Maximum Output Models Maximum Output
HP03-1/04-24
15W
HP05-1/12-24
55W
HP03-1/05-240
15W
HP05-1/13-24
58W
HP03-1/07-240
20W
HP05-1/14-24
60W
HP03-1/08-24
30W
HP05-1/14-28
60W
HP03-1/09-240
25W
HP05-1/15-240
58W
HP03-1/11-240
30W
HP05-1/20-240
60W
HP04-1/04-24
10W
HP05-1/22-24
70W
HP04-1/05-240
10W
HP06-2/04-24
18W
HP04-1/07-240
15w
HP06-2/05-24
20w
HP04-1/08-24
15W
HP06-2/05-240
20W
HP04-1/09-240
18W
HP06-2/05-48
20W
HP04-1/11-240
20W
HP06-2/07-240
50W
HP04-1/13-240
22W
HP06-2/09-240
70W
HP04-1/13-240
32W
HP06-2/10-24
80W
HP05-1/04-24
20W
HP06-2/11-240
110W
HP05-1/05-24
22W
HP06-2/13-240
145W
HP05-1/05-240
20W
HP06-2/15-240
160W
HP05-1/07-240
25W
HP06-2/18-240
180W
HP05-1/09-240
30W
HP06-2/20-240
200W
HP05-1/10-24
50w
HP06-2/22-24
200W
HP05-1/11-240
35W
HP06-2/24-240
225W
*    HP01-2/15-240R1 (250mm Length, L)
140W
*    HP01-2/15-240R2 (400mm Length, L)
160W
*    HP01-2/15-240R3 (70mm Length, L)
100W
*    HP01-4/15-240R1 (250mm Length, L)
280W
*    HP01-4/15-240R2 (400mm Length, L)
320W
Note: -24 represents 12 - 30v operating voltage
        - 48 represents 60 - 60v operating voltage
        - 240 represents 100 - 240v operating voltage
STANDARD LEAD LENGTH 100mm
 
   
Copyright © 2002 European Thermodynamics Ltd. All rights reserved.
         ETL terms and conditions apply.